Cyanide Analyzer
Get Latest PricePrinciple: | Isonicotinic acid-barbituric acid spectrophotometry |
Range : | 0~1 / 0~2mg/L |
Detection limit : | 0.01mg/L |
Resolution : | 0.01mg/L |
Permissible error: | 10% FS |
Repeatability : | 5%FS |
Principle: | Isonicotinic acid-barbituric acid spectrophotometry |
Range : | 0~1 / 0~2mg/L |
Detection limit : | 0.01mg/L |
Resolution : | 0.01mg/L |
Permissible error: | 10% FS |
Repeatability : | 5%FS |
Principle:
This product uses the isonicotinic acid-barbituric acid spectrophotometry to determine the concentration of cyanide in water samples. After the water sample and the regulator are mixed, the cyanide ions in the water sample react with chloramine T to generate cyanogen chloride, which reacts with isonicotinic acid to generate glutaraldehyde after hydrolysis, and then reacts with barbituric acid to generate a purple-blue compound. The monitor detects the change in color and converts this change into a vapor value for output.
Features:
touch panel
Multi range, automatic switching
Level 3 operation permissions
State self diagnosis function
Abnormal or power outage data protection
Built in multiple communication protocols
Scheduled testing and automatic verification
Power off and restart, automatic emptying, cleaning, and reset
Running log records, process and operation records can be checked
remote monitoring, remote operation instructions
Timed testing, automatic verification
Parameters:
Measure factor | Cyanide |
Principle | Isonicotinic acid-barbituric acid spectrophotometry |
Range | 0~1 / 0~2mg/L (switchable and expandable) |
Detection limit | 0.01mg/L |
Resolution | 0.01mg/L |
Permissible error | 10% FS |
Repeatability | 5%FS |
Zero drift | 5%FS |
Range drift | 10%FS |
Measuring cycle | Min. 30 minutes; Digestion time: 5~60 minutes (adjustable) |
Sampling period | Timing analysis, interval analysis, remote control |
Calibration cycle | Automatic calibration/manual calibration |
Maintenance cycle | 1 month (about 1 hour each time) |
Reagent consumption | About RMB 0.5 per sample |
Data storage | More than 1 year of data storage |
Input | Switch |
Output | 1 RS232, 1 RS485, 2 4-20mA |
Power supply | AC(220~240) |
Working current | 5A |
Size | LWD: 1500*500*450mm |
Privacy statement: Your privacy is very important to Us. Our company promises not to disclose your personal information to any external company with out your explicit permission.